1. Due to the different water-cooling plates matched with various models of the server, please consult customer service before placing an order.(We support customizing the water-cooled plates of all servers)
|
|
|
|
|
||||
2. It is recommended to use the LIANLI overclocking power supply to achieve overclocking. Use the original 4000W power supply. If the power cannot be satisfied, overclocking will easily damage the machine.
|
|
|
|
|
||||
3. Before powering on, please run the water cycle to check that there is no overflow, and then run the machine. The initial installation should be observed for a period of time.
|
|
|
|
|
||||
4. This set of plans is not equipped with external inlet and outlet water pipes/trachea pipes. If you need to customize, you can consult customer service.
|
|
|
|
|
||||
5. For detailed installation videos and pictures, please consult customer service.
|
|
|
|
|
||||
6.There are many sellers of water-cooled plates (water blocks) on the market, and the quality is uneven. LIANLI regardless of the drilling process of the aluminum plate, the selection of the interface, the metal material used for the interface, and the highest level of thermal grease with a coefficient of 5.0 (w/m-k). They are better and safer than those produced by other factories
|
|
|
|
|
Product Specifications
|
|
|
|
|
||||
Can improve server performance by 30-70%, effectively solving the problem of chip heat dissipation
|
|
|
|
|
||||
water cooling plate
|
Specification:
|
118*178*14.5mm
|
quantity:
|
6 pcs manifold*4
|
||||
pipe connector
|
Specification:
|
1CM*0.8CM
|
quantity:
|
24 pcs(installed on manifold and water cooling plate)
|
||||
pipe connector
|
Specification:
|
2CM*1.2CM
|
quantity:
|
4 pcs (installed on the manifold)
|
||||
pipe
|
Specification:
|
0.8CM
|
quantity:
|
1 meter
|
||||
Recommended use environment:
|
|
|
|
|
||||
In an environment where water is convenient to obtain around rivers and ravines or the cost of water is low, the method of entering cold water into hot water and discharging it can be used directly! If it is used in buildings such as workshops and computer rooms, it needs to be equipped with water cooling towers or refrigerators for water cooling. The freezing prevention pipes in alpine areas can use ethylene glycol liquids with different concentrations to replace water according to the temperature!
|
|
|
|
|
||||
Recommended cooling tower selection
|
|
|
|
|
||||
The heat dissipation of a single server overclocked to 7000W is about 1600W, and the required cooling capacity is about 3600W.According to the parameters provided by the manufacturer as shown in the figure below, the parameters of each manufacturer have a small deviation. For example, the cooling capacity of a 10T tower is 58k/3.6kw=16.2. The heat dissipation is less than the cooling capacity, so 20% of the heat dissipation should be reserved, 16.2-16.2x20%=13 units, that is, a 10T cooling tower can bring 13 units. Combined with other specifications of cooling towers, the water tower per tonnage can be calculated. The number of machines that can be brought is 1.3 units
|
|
|
|
|
||||
Pump selection
|
|
|
|
|
||||
The water cooling plate adopts the inlet and outlet pipes of 12mm. According to the calculation, the 12mm pipe is calculated as 1 ton per hour, the number of machines x 1 ton/hour = the flow rate of the pump
|
|
|
|
|
||||
water cooling plate size:
|
Package weight
|
5KG
|
|
|
||||
|
Package dimensions
|
300*212*152MM
|
|
|
Step 1: Remove the front and rear fans of the server.
|
|
|
|
|
||||
Step 2: Removing the air-cooled computing motherboard
|
|
|
|
|
||||
Step 3: Align the screw holes on the hash board, install the water-cooling board, and pay attention to the direction of the water-cooling board's water inlet.
|
|
|
|
|
||||
Step 4: Put the hash board back into the machine, insert the water pipe of the water divider, and connect it to the hash board,and each horizontal component is connected to a water divider.
|
|
|
|
|
||||
Step 5: Install the front fan and the rear water cooling plate back, and use the provided 12mm water pipe joint to install and fix the water distributor to the water cooling plate.
|
|
|
|
|
||||
Step 6: Turn on the water circulation, check all connection positions, and check whether there is overflow at the faucet. Be sure to run the water circulation first to check that there is no overflow, and then run the machine. The initial installation should be observed for a while.
|
|
|
|
|
Our R&D and production base is over 10,000 m2, with 10 years of industry experience, rich technology accumulation and advanced production technology, producing more than 300 different products.